五月婷婷中文_总裁与秘书啪啪日常H_精品视频国产香蕉尹_亚洲图片日本视频免费_男女乱滛免费视频网站_藏经阁91福利私人试看_99久久国产综合精品一级_国产精品午夜福利电影_另类福利亚洲丝袜激情在线_免费在线观看最新理论片

Fault diagnosis and maintenance skills of water ring vacuum pump

Addtime: 2020-07-18 Browse times: 2097

1. The power consumption of vacuum pump is too high


(1) the solution to the wrong rotation direction: check the rotation direction.


(2) impeller damage solution: check the impeller and replace it as required.


(3) the solution to the seizure of rotating parts: check whether the clearance of internal wear parts is normal.


(4) shaft bending solution: straighten the shaft or replace it as required.


2. The vacuum pump will stop after running for a while


(1) solution for too high suction head: check the existing net head (too small or too long inlet pipeline will cause great friction loss).


(2) solution for impeller or pipeline blockage: check whether there are obstacles.


(3) solution for air generation or leakage of inlet pipeline: check whether there is air hole and / or air leakage in the inlet pipeline.


(4) the packing or seal in the stuffing box is worn, so that the air leaks into the vacuum pump shell. Solution: check the packing or seal and replace it as required, and check whether the lubrication is normal.


3. No liquid supply, insufficient liquid supply or insufficient pressure:


(1) the vacuum pump is not filled with water or properly vented. Solution: check whether the vacuum pump shell and inlet pipeline are fully filled with liquid.


(2) solution for too low speed: check whether the wiring of the motor is correct, whether the voltage is normal or whether the steam pressure of the turbine is normal.


(3) solution for too high water head of the system: check the water head of the system (especially the friction loss).


(4) solution for too high suction head: check the existing net head (too small or too long inlet pipeline will cause great friction loss).


(5) solution for impeller or pipeline blockage: check whether there are obstacles.

 